Automation: Control Object

The Control Object Tool Bar allows user to insert control objects, see Fig. Digital In “Digital In” is used to check the input potential signal is correct or not when marking. Users can set potential signal (high or low) at IN 1~8, see Fig. If the input signal is correct, then the system will do… Continue reading Automation: Control Object

Automation: Automation and I/O

If users want to apply this system in automatic process, all they need to do is understanding how the system works with I/O signals and do the right setting. Time Sequence Signal Program Ready/Mark Ready Program Ready and Mark Ready signals are programmable. System integrators are able to plan the signal as Program Ready or… Continue reading Automation: Automation and I/O

How to Use the Function of Mark on Fly?

Without the “Mark On Fly” function, the marking result will be incorrect while the working pieces are moving. Enable this function the system will pursue the object’s position and revise it to make sure the marking result is correct. Enable Mark on Fly Users can enable “Mark on Fly” function from「File Menu」→「Option」→「System」→「Mark on Fly」, see… Continue reading How to Use the Function of Mark on Fly?

How to Use the Function of Lens Correction?

“Lens Correction” function is used to fix the distortion resulted from Lens characteristics or optical problems. If the lens correction has been completed, but the mark result still hassome problems such asunfocused or ratio inaccuracy, usersneed to adjust these parameters from the “Work Area” page under “Property Table.” Lens Manager Enter “Lens Manger” form 「File」→「Option」→… Continue reading How to Use the Function of Lens Correction?