Open the AI icon file in EZCAD and it is found that it is a single line file and cannot be filled

The AI icon file is opened as a single-line file in EZCAD and cannot be filled. How do I solve it? When designing vector graphics, how can I make EZCAD recognize it as a double-line icon that can be filled? The CDR x7 version has a function that can solve it with one key: Object – Enable contour. This… Continue reading Open the AI icon file in EZCAD and it is found that it is a single line file and cannot be filled

How to Import Fonts Into Ezcad2?

Can I import fonts to ezcad 2? How to? Yes. If it is a PC font in ttf format, put it directly into the Fonts folder of your computer system. If it is a font such as JSF, SHX, etc., copy it to the FONT folder of the marking software.

How to use one PC to control multiple laser marking machine software ezcad for marking?

Multiple marking boards are required to control multiple lasers and gavlo, and connected to the same computer. The marking boards need to enable the multi-head function and dial different serial numbers on the DIP switch. Each marking board is connected to the PC, and the multi-head marking software is opened to set the marking area… Continue reading How to use one PC to control multiple laser marking machine software ezcad for marking?

“current LMC board is not for Fiber Laser”, how to troubleshoot?

The laser marking machine does not work, the marking software shows that “current LMC board is not for Fiber Laser”, how to troubleshoot? First, set the marking parameters: Param (F3) – Laser Control, Laser type – Fiber, Fiber – Serial, select your laser source correctly If the problem is not solved, continue troubleshooting: ①The laser power is… Continue reading “current LMC board is not for Fiber Laser”, how to troubleshoot?

Can the marking software enable remote control marking?

Yes, it is possible. In the laser marking software, you need to draw a normal text first, and then check “Enable Variable Text” – “Add” – “TCP/IP Communication” or “Serial Communication”, you only need to establish communication with the software to achieve data reception. The network port and serial port only need to use common TCP/IP and RS232 communication protocols to… Continue reading Can the marking software enable remote control marking?

Red light size is not right; it is unstable and spinning; not clear?

The red light is not the right size partly because galvanometer correction has not been done, so galvanometer correction can be done first; The red light is unstable and spinning, you can click “F3 parameters”-“Other”-“Red light pointer“, by increasing the red light speed, the situation of red light can be changed; If the red light is not… Continue reading Red light size is not right; it is unstable and spinning; not clear?